Pumps Lubricants Lubrication
Systems
Pump Rentals Hydraulics

View CartView RFQ's  | Shipping 
 | Tax 
 | Terms 
 Shopping Cart  0 Items 
 Request for Quote  0 Items 
All Categories > Lift Station Monitoring Equipments > Cellular Sewage Lift Station Monitors > Item # XR50  
    Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # XR50, Cellular Sewage Lift Station Monitors

List Price QUOTE


Cellular Sewage Lift Station Monitor

larger image
OmniSite lift station monitors are the industry’s easiest to install, setup and use!

Designed for Wastewater Treatment
OmniSite monitors are the only patented product of their kind and were developed specifically for wastewater treatment systems. Every feature on the XR50 was designed with the customer in mind, including the terminal blocks, universal voltage inputs, on-board display and LED’s.

Simple to Use
Installation is simple enough for customers to do themselves and setup takes just a few minutes: by visiting OmniSite’s website to enter lift station settings and establish a "call out" list for alarm notification, your system is ready to go. A combination of cellular telephone and web-based technology makes it possible to monitor pump stations any day, any time, from any computer.

Peace of Mind
OmniSite’s XR50 can predict problems at pump stations before they occur by analyzing conditions and making that data available to you instantaneously. The XR50 tracks pump run time, pump cycles, GPM, draw down times, inflow, rainfall and pulses from a flow meter. When an alarm occurs, you’ll be notified within seconds – quickly enough to correct the situation and avoid costly, environmental problems.

OmniSite lift station monitors are self-contained, require no additional software and need minimal maintenance, making them the most affordable monitors available!




Quick Overview · Specifications · How OmniSite Works

Quick Overview

The Essentials:
  • (7) Universal voltage inputs (Includes Rain and Pulse inputs as these can also be used as alarm inputs)
  • (3) Inputs to monitor pump activity
  • (2) Pulse inputs (i.e. flow meters)
  • (1) Input to analyze rainfall
  • Transmits/Receives using GSM
  • Optional NEMA 4X enclosure


  • Website Features:
  • Quick setup and easy to use
  • Intuitive navigation
  • Interactive mapping by Yahoo!™
  • Detailed graphs and charts
  • Real time weather updates
  • Easy to organize and print reports




  • Specifications

    I/O: Accepts (10) Universal Inputs- any voltage in the range of + 12 VDC or VAC to + 120 VDC or VAC. Opto-isolated 4000 VAC isolation

    (3) Pulse Inputs: 0–5 Hz from dry contact or open collector device (1 pulse input reserved for 0.01" pulsing rain gauge)

    Input Power: 85–240 VAC ± 10 % at 0.5 A max or optional 12 VDC at 2 A max

    Terminal Blocks: gray color, removable style, spring-clamp accepts #14–22 AWG solid or stranded wire

    External Power Source: 15 VDC at 100 mA battery backed internal power source available for powering external un-powered alarm contacts

    SD Memory Card Slot: on-board SD memory card slot for data logging and software updates

    Battery Backup: Internal 12 VDC, rechargeable 800 mA/h sealed lead acid battery rated for 4 hours backup during AC power loss

    Operating Temperature: -20–150 °F

    Operating Humidity: 0–90 % RH, non-condensing

    Radio: Quad Band GSM cellular transceiver 850/900/1800/1900, -106 dB sensitivity (typical), Class 4 (2 W at 850/900 MHz) class 1 (1 W at 1800/1900 MHz). Certification FCC Parts 15, 22, 24, GCF Ver 3.21.1, PTCRB Ver 3.7.1

    Antenna: Internal 3 dBi omni-direction Phantom antenna suitable for most applications. Optional remote mount high gain antennas and cables available

    Display: 2 line x 16 Char white background LCD w/backlight. Includes (4) "easy-use" navigation buttons

    Personal ID Key Reader: Smart key reader to identify maintenance personnel. (1) smart key included

    Enclosure: Standard unit is hinged painted steel design suitable for direct panel mount. Optional NEMA 4X polycarbonate enclosure w/ stainless locking hasps and solid or clear cover available

    Dimensions: panel mount – 8.5" W x 8.2" H x 3.5" D – with optional NEMA 4X enclosure – 12" H x 10" W x 4" D

    Weight: Standard panel mount - 6.0 lbs, with NEMA 4X enclosure - 6.8 lbs

    Certification: UL pending

    Protection: US Patent #7, 228, 129

    The XR50 is perfect for monitoring digital alarm inputs and analyzing trends at a lift station. For additional monitoring options – including analog process variables and actual pump control – see OmniSite’s Crystal Ball.



    How OmniSite Works

    OmniSite relies on a combination of cellular telephone and web-based technology. The XR50 is installed at pump stations and sends a wireless signal to the local cellular tower. That signal is bounced to OmniSite’s web interface, where customers can log on – any day, any time, from any computer – and see how each pump station is operating. A "call out" list is set up online, so that when an alarm is triggered at a lift station, identified operators are contacted immediately. Because OmniSite engineers recognize today’s fast-paced busy world, that notification comes by way of text message, email or call to your cellular or hard-wired phone.



     MORE IMAGES 

    · XR50 - OmniSite S-Plug and Play GuardDog Software

    · XR50 - How OmniSite Works


    Request Information
    Site created by ThomasNet Web Solutions